KFD2-HLC-Ex1.D倍加福KFD2-SOT3-Ex1.LB

    KFD0-HMS-16
    HART Multiplexer Slave
    16-channel, No external power required, HART field device input (revision 5 to 7), Used with HART Multiplexer Master KFD2-HMM-16, Up to SIL 3 acc. to IEC 61508
    
    KFD0-RO-Ex2
    Relay Module
    2-channel isolated barrier, 24 V DC supply (loop powered), Logic input 15 V DC ... 30 V DC, non-polarized, Relay contact output, Up to SIL 3 acc. to IEC 61508
    
    KFD0-SCS-Ex1.55
    SMART Current Driver/Repeater
    1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, HART I/P or transmitter power supply, Low voltage drop, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex protection, Transfer direction: to the field / to the control system
    
    KFD0-SD2-Ex2.1045
    Solenoid Driver
    2-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 10 V DC, Up to SIL 3 acc. to IEC 61508
    
    KFD2-CRG2-Ex1.D
    Transmitter Power Supply
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA ... 20 mA, 2 relay contact outputs, Adjustable energized/de-energized delay, Programmable high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-EB2.R4A.B
    Redundant Power Feed Module
    Interface for Power Rail, Used for redundant configuration, Supply current ≤ 4 A, Replaceable fuse, Relay contact output, reversible, LED status indication
    
    KFD2-GUT-Ex1.D
    Temperature Converter with Trip Values
    1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA ... 20 mA, 2 relay contact outputs, Configurable by PACTware or keypad, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-HMM-16
    HART Multiplexer Master
    16-channel, 24 V DC supply (Power Rail), HART field device input (revision 5 to 7), Up to 15 KFD0-HMS-16 slave units can be connected, Up to SIL 3 acc. to IEC 61508
    
    KFD2-SCD2-Ex1.LK
    SMART Current Driver
    1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART I/P and valve positioner, Line fault detection (LFD), Accuracy 0.1 %, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
    
    KFD2-SCD2-Ex2.LK
    SMART Current Driver
    2-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART I/P and valve positioner, Line fault detection (LFD), Accuracy 0.1 %, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
    
    KFD2-SL2-Ex2.B
    Solenoid Driver
    2-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.7 V DC, Logic input, non-polarized, Up to SIL 2 acc. to IEC 61508
    
    KFD2-SOT3-Ex1.LB
    Switch Amplifier
    1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
    
    KFD2-SOT3-Ex2
    Switch Amplifier
    2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
    
    KFD2-STC5-1
    SMART Transmitter Power Supply
    1-channel ** conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA current sink/current source, Terminals with test points, Up to SIL 2 acc. to IEC 61508
    
    KFD2-STC5-1.2O
    SMART Transmitter Power Supply
    1-channel ** conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA, current sink/current source, Terminals with test points, Up to SIL 3 acc. to IEC 61508
    
    KFD2-STC5-Ex1
    SMART Transmitter Power Supply
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA current sink/current source, Terminals with test points, Up to SIL 2 acc. to IEC 61508
    
    KFD2-STC5-Ex1.2O
    SMART Transmitter Power Supply
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA, current sink/current source, Terminals with test points, Up to SIL 3 acc. to IEC 61508
    
    KFD2-STC5-Ex2
    SMART Transmitter Power Supply
    2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA current sink/current source, Terminals with test points, Up to SIL 2 acc. to IEC 61508
    
    KFD2-UFC-Ex1.D
    Frequency Converter with Trip Values
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input for NAMUR sensors or dry contacts, Input frequency 1 mHz ... 5 kHz, Current output 0/4 mA ... 20 mA, Relay contact and transistor output, Start-up override, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-USC-1.D
    Signal Converter with Trip Value
    1-channel ** conditioner, 24 V DC supply (Power Rail), Scaleable current or voltage input, Current or voltage output, Relay contact output, Configurable by keypad, Line fault detection (LFD)
    
    KFD2-UT2-Ex1
    Universal Temperature Converter
    1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-UT2-Ex2
    Universal Temperature Converter
    2-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as ** splitter (1 input and 2 outputs), Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-VR4-Ex1.26
    Voltage Repeater
    1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V ... -20 V, Vibration sensor inputs, Voltage/current field supply, Voltage output 0 V ... -20 V, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the control system
    
    KFD0-CC-1
    Current/Voltage Converter
    1-channel ** conditioner, 24 V DC supply (loop powered), Current or voltage input, Output: 4 ... 20 mA, Potentiometer or DIP switch selectable ranges, Line fault detection (LFD)
    
    KFD0-CC-Ex1
    Current/Voltage Converter
    1-channel isolated barrier, 24 V DC supply (loop powered), Current or voltage input, Output: 4 ... 20 mA, Potentiometer or DIP switch selectable ranges, Line fault detection (LFD)
    
    KFD0-CS-Ex1.50P
    Repeater
    1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system
    
    KFD0-CS-Ex1.51P
    Current Driver/Repeater
    1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 0 mA ... 40 mA, I/P or transmitter power supply, Accuracy 1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system
    
    KFD0-CS-Ex1.54
    Repeater
    1-channel isolated barrier, 24 V DC supply (loop powered), SMART fire alarm input, Current input 1 mA ... 20 mA, Up to SIL 3 acc. to IEC 61508, Transfer direction: to the control system
    
    KFD0-CS-Ex2.51P
    Current Driver/Repeater
    2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 0 mA ... 40 mA, I/P or transmitter power supply, Accuracy 1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system
    
    KFD0-RSH-1.4S.PS2
    Relay Module
    1-channel ** conditioner, 24 V DC supply (loop powered), Logic input 20 V DC ... 26.5 V DC, non-polarized, Fail-safe relay contact output for de-energized and energized to safe function , Test pulse immunity, Up to SIL 3 acc. to IEC 61508
    
    KFD0-SCS-1.55
    SMART Current Driver/Repeater
    1-channel ** conditioner, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, HART I/P or transmitter power supply, Low voltage drop, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system
    
    KFD0-SD2-Ex1.10100
    Solenoid Driver
    1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 100 mA at 10 V DC, Up to SIL 3 acc. to IEC 61508
    
    KFD0-SD2-Ex1.1180
    Solenoid Driver
    1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 80 mA at 11 V DC, Up to SIL 3 acc. to IEC 61508
    
    KFD0-SD2-Ex2.1245
    Solenoid Driver
    2-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 12 V DC, Up to SIL 3 acc. to IEC 61508
    
    KFD0-TR-1
    RTD Converter
    1-channel ** conditioner, 24 V DC supply (loop powered), 2- or 3-wire Pt100 RTD input, Output 4 mA ... 20 mA, temperature linearization selectable, DIP switch selectable ranges, Sensor breakage detection
    
    KFD0-TR-Ex1
    RTD Converter
    1-channel isolated barrier, 24 V DC supply (loop powered), 2- or 3-wire Pt100 RTD input, Output 4 mA ... 20 mA, temperature linearization selectable, DIP switch selectable ranges, Sensor breakage detection
    
    KFD2-BR-1.PA.1500
    Basic Segment Coupler
    Output: 24 ... 26 V/400 mA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, Up to 1.5 MBit auto-adapting
    
    KFD2-CD-1.32
    Current Driver
    1-channel ** conditioner, 24 V DC supply (Power Rail), Current input 0 mA ... 20 mA, Current output 0 mA ... 20 mA, Accuracy 0.1 %, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field
    
    KFD2-CRG2-1.D
    Transmitter Power Supply
    1-channel ** conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA ... 20 mA, 2 relay contact outputs, Adjustable energized/de-energized delay, Programmable high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-DWB-1.D
    Rotation Speed Monitor
    1-channel ** conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Input frequency 1 mHz ... 12 kHz, 2 relay contact outputs, Start-up override, Configurable by keypad, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-DWB-Ex1.D
    Rotation Speed Monitor
    1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Input frequency 1 mHz ... 5 kHz, 2 relay contact outputs, Start-up override, Configurable by keypad, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-EB2
    Power Feed Module
    Interface for Power Rail, Supply current ≤ 4 A, Replaceable fuse, Relay contact output, reversible, LED status indication
    
    KFD2-ER-1.6
    Conductivity Switch Amplifier
    1-channel ** conditioner, 24 V DC supply (Power Rail), Level sensing input, Adjustable range 5 kΩ ... 150 kΩ, Relay contact output, Minimum/maximum control
    
    KFD2-ER-Ex1.W.LB
    Conductivity Switch Amplifier
    1-channel isolated barrier, 24 V DC supply (Power Rail), Level sensing input, Adjustable range 1 kΩ ... 150 kΩ, Relay contact output, Fault relay contact output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD)
    
    KFD2-GS-1.2W
    Current/Voltage Trip Value
    1-channel ** conditioner, 24 V DC supply (Power Rail), Current and voltage input, 2 relay contact outputs, Programmable high/low alarm, Configurable via DIP switches and potentiometer, Terminal blocks with test sockets
    
    KFD2-GUT-1.D
    Temperature Converter with Trip Values
    1-channel ** conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA ... 20 mA, 2 relay contact outputs, Configurable by PACTware or keypad, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-HLC-Ex1.D
    HART Loop Converter
    1-channel isolated barrier, 24 V DC supply (Power Rail), HART field device input with transmitter power supply, Usable as ** splitter (1 input and several outputs), 3 analog outputs 4 mA ... 20 mA, Sink and source mode output, Configurable by keypad
    
    KFD2-PT2-Ex1
    Potentiometer Converter
    1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Voltage output 0 V ... 10 V, Lead resistance compensation adjustment, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508
    
    KFD2-PT2-Ex1-5
    Potentiometer Converter
    1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Current output 4 mA ... 20 mA, Lead resistance compensation adjustment, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508
    
    KFD2-RCI-Ex1
    Solenoid Driver
    1-channel isolated barrier, 24 V DC supply (Power Rail), Output 20.4 mA at 13.5 V DC, 19 V DC ... 30 V DC input, Line fault detection (LFD), Conformal coating, Up to SIL 3 acc. to IEC 61508

    上海創(chuàng)弗實(shí)業(yè)有限公司專注于安川伺服電機(jī),羅斯蒙特變送器羅斯蒙特分析儀,庫伯勒編碼器等

  • 詞條

    詞條說明

  • 圖爾克型號:FCS-G1/2A4P-LIX-H1141/L080

    圖爾克型號:FCS-G1/2A4P-LIX-H1141/L080貨號:6870055圖爾克流量傳感器型號:FCS-N1/2A4-NAEX-H1141貨號:6871322圖爾克流量型號:FCI-D15A4P-ARX-H1140貨號:6870671圖爾克流量型號:FCI-D10A4P-LIX-H1141/A貨號:6870639圖爾克流量具有與流體模塊一致的功能分體式探頭型號:FCST-A4-NA-H1

  • F2-JB-I#.*

    R-SP-E12 Segment Protector for Cabinet Installation Segment Protector for Cabinet Installation, 12 increased safety outputs (Ex e), Short circuit current limitation per output, Segment Protector in Zo

  • 228-02-20-5-461電導(dǎo)率傳感器

    Rosemount? 228 環(huán)形電導(dǎo)率傳感器 過程連接件 1-1/2 英寸 MNPT 閥門類型 推薦閥門:1-1/2 英寸全徑球閥 結(jié)構(gòu)材料 316 不銹鋼,Teflon1,乙烯聚丙烯 222 流通式環(huán)形電導(dǎo)率傳感器包括襯聚四氟乙烯短管、環(huán)形電、溫度補(bǔ)償元件、碳鋼連接法蘭和 20 英尺 (6.1 米)電纜。222 傳感器可以匹配的分析儀:1054A、1054B、2054、1055、1056、

  • LMS511-11100傳感器LMS511-10100 PRO

    LMS511-11100 Lite訂貨號:1054155產(chǎn)品系列:LMS5xx產(chǎn)品系列:2D LiDAR傳感器 工作區(qū)域:1 m...80 m 分辨率范圍:Standard Resolution 開啟角度:水平的(190°) 外殼防護(hù)等級:IP65,IP67 顏色:灰色(RAL 7032) 集成應(yīng)用:評估區(qū)域 連接類型:4 x M12圓形插頭連接器 掃描頻率:25 Hz/35 Hz/50 Hz/7

聯(lián)系方式 聯(lián)系我時,請告知來自八方資源網(wǎng)!

公司名: 上海創(chuàng)弗實(shí)業(yè)有限公司

聯(lián)系人: 張曉龍

電 話: 18001664790

手 機(jī): 18001664790

微 信: 18001664790

地 址: 上海松江方松辰塔路2號

郵 編:

網(wǎng) 址: chuangfusy.b2b168.com

八方資源網(wǎng)提醒您:
1、本信息由八方資源網(wǎng)用戶發(fā)布,八方資源網(wǎng)不介入任何交易過程,請自行甄別其真實(shí)性及合法性;
2、跟進(jìn)信息之前,請仔細(xì)核驗(yàn)對方資質(zhì),所有預(yù)付定金或付款至個人賬戶的行為,均存在詐騙風(fēng)險,請?zhí)岣呔瑁?
    聯(lián)系方式

公司名: 上海創(chuàng)弗實(shí)業(yè)有限公司

聯(lián)系人: 張曉龍

手 機(jī): 18001664790

電 話: 18001664790

地 址: 上海松江方松辰塔路2號

郵 編:

網(wǎng) 址: chuangfusy.b2b168.com

    相關(guān)企業(yè)
    商家產(chǎn)品系列
  • 產(chǎn)品推薦
  • 資訊推薦
關(guān)于八方 | 八方幣 | 招商合作 | 網(wǎng)站地圖 | 免費(fèi)注冊 | 一元廣告 | 友情鏈接 | 聯(lián)系我們 | 八方業(yè)務(wù)| 匯款方式 | 商務(wù)洽談室 | 投訴舉報
粵ICP備10089450號-8 - 經(jīng)營許可證編號:粵B2-20130562 軟件企業(yè)認(rèn)定:深R-2013-2017 軟件產(chǎn)品登記:深DGY-2013-3594
著作權(quán)登記:2013SR134025
Copyright ? 2004 - 2024 b2b168.com All Rights Reserved