KFD2-VM-Ex1.35.L倍加福KFD2-RSH-1.2D.FL2

    KFD2-RSH-1.2D.FL2
    Relay Module
    1-channel ** conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 8 V DC ... 60 V DC, Relay contact output for de-energized to safe function, Line fault transparency (LFT), Diagnostic function, Up to SIL 3 acc. to IEC 61508, Up to PL e acc. to EN/ISO 13849
    
    KFD2-RSH-1.2D.FL3
    Relay Module
    1-channel ** conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 50 V AC ... 230 V AC, 60 V DC ... 110 V DC, Relay contact output for de-energized to safe function, Line fault transparency (LFT), Diagnostic function, Up to SIL 3 acc. to IEC 61508, Up to PL e acc. to EN/ISO 13849
    
    KFD2-RSH-1.2E.L2
    Relay Module
    1-channel ** conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 8 V DC ... 60 V DC, Relay contact output for energized to safe function , Line fault transparency (LFT), Diagnostic function, Up to SIL 3 acc. to IEC 61508
    
    KFD2-RSH-1.2E.L3
    Relay Module
    1-channel ** conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 50 V AC ... 230 V AC, 60 V DC ... 110 V DC, Relay contact output for energized to safe function , Line fault transparency (LFT), Diagnostic function, Up to SIL 3 acc. to IEC 61508
    
    KFD2-SH-Ex1
    Switch Amplifier
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input for approved dry contacts or SN/S1N sensors, Relay contact output, Fault indication output, Line fault detection (LFD), Up to SIL 3 acc. to IEC 61508, Up to PL d acc. to EN/ISO 13849
    
    KFD2-SL2-Ex2
    Solenoid Driver
    2-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.7 V DC, Logic input, non-polarized, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
    
    KFD2-SLD-Ex1.13100
    Solenoid Driver
    1-channel isolated barrier, 24 V DC supply (Power Rail), Logic input, Output 100 mA at 13 V DC, Alternating outputs for the operation of solenoids with 2 coils, High output power for IIB gas group, Line fault transparency (LFT), Test pulse immunity, Up to SIL 3 acc. to IEC 61508
    
    KFD2-SOT3-Ex2.IO
    Switch Amplifier
    2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
    
    KFD2-SR2-Ex1.W
    Switch Amplifier
    1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-SR2-Ex1.W.LB
    Switch Amplifier
    1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as ** splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-SR2-Ex2.W
    Switch Amplifier
    2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-SR3-Ex2.2S
    Switch Amplifier
    2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as ** splitter (1 input and 2 outputs), 2 x 2 relay contact outputs with AND logic, Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
    
    KFD2-SRA-Ex4
    Switch Amplifier
    4-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 50 % less wiring, 2:1 technology, Relay contact output, Line fault detection (LFD), Reversible mode of operation
    
    KFD2-ST3-Ex1.LB
    Switch Amplifier
    1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Usable as ** splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
    
    KFD2-ST3-Ex2
    Switch Amplifier
    2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Active transistor output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508
    
    KFD2-STC4-Ex1.2O-Y1
    SMART Transmitter Power Supply, Output Current Sink
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA, current sink, Terminal blocks with test sockets, Up to SIL 3 acc. to IEC 61508
    
    KFD2-STC4-Ex2-Y1
    SMART Transmitter Power Supply, Output Current Sink
    2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire SMART transmitters, Output 0/4 mA ... 20 mA current sink, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508
    
    KFD2-STC5-2
    SMART Transmitter Power Supply
    2-channel ** conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA current sink/current source, Terminals with test points, Up to SIL 2 acc. to IEC 61508
    
    KFD2-STC5-Ex1.H
    SMART Transmitter Power Supply
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Output 0/4 mA ... 20 mA current sink/current source, Terminals with test points, High field voltage 17 V DC, Up to SIL 2 acc. to IEC 61508
    
    KFD2-STV4-Ex1.2O-1
    SMART Transmitter Power Supply
    1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0/1 V ... 5 V, Terminal blocks with test sockets, Up to SIL 3 acc. to IEC 61508
    
    KFD2-UFC-1.D
    Frequency Converter with Trip Values
    1-channel ** conditioner, 24 V DC supply (Power Rail), Input for 2- or 3-wire sensors, NAMUR sensors or dry contacts, Input frequency 1 mHz ... 10 kHz, Current output 0/4 mA ... 20 mA, Relay contact and transistor output, Start-up override, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-UT2-1
    Universal Temperature Converter
    1-channel ** conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-UT2-2
    Universal Temperature Converter
    2-channel ** conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as ** splitter (1 input and 2 outputs), Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-VR-Ex1.18
    Voltage Repeater
    1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V ... 12 V, Voltage output 0 V ... 12 V, Transfer direction: to the control system
    
    KFD2-VR2-Ex1.50M
    Voltage Repeater
    1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 mV ... ± 50 mV, Voltage output 0 mV ... ± 50 mV, Selectable up/downscale sensor breakage detection, Transfer direction: to the control system
    
    KFD2-WAC2-1.D
    Strain Gauge Converter
    1-channel ** conditioner, 24 V DC supply (Power Rail), Strain gauge input (full or half bridge), Output 0 mA ... ± 20 mA or 0 V ... ± 10 V, 2 relay contact outputs, Programmable high/low alarm, Configurable by PACTware or keypad, RS-485 interface, Line fault detection (LFD)
    
    KFD0-CS-Ex2.52
    Repeater
    2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, Accuracy 0.1 %, Entity parameter Io/Isc = 0 mA, Transfer direction: to the control system
    
    KFD0-CS-Ex2.54
    Repeater
    2-channel isolated barrier, 24 V DC supply (loop powered), SMART fire alarm input, Current input 1 mA ... 20 mA, Up to SIL 3 acc. to IEC 61508, Transfer direction: to the control system
    
    KFD2-ER-2.W.LB
    Conductivity Switch Amplifier
    2-channel ** conditioner, 24 V DC supply (Power Rail), Level sensing input, Adjustable range 1 kΩ ... 150 kΩ, Relay contact output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD)
    
    KFD2-HLC-Ex1.D.2W
    HART Loop Converter
    1-channel isolated barrier, 24 V DC supply (Power Rail), HART field device input with transmitter power supply, Usable as ** splitter (1 input and several outputs), 2 relay contact outputs (change-over contacts), 3 analog outputs 4 mA ... 20 mA, Sink and source mode output, Configurable by keypad
    
    KFD2-PT2-Ex1-1
    Potentiometer Converter
    1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Voltage output 0 V ... 5 V, Lead resistance compensation adjustment, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508
    
    KFD2-PT2-Ex1-4
    Potentiometer Converter
    1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Current output 0 mA ... 20 mA, Lead resistance compensation adjustment, Accuracy 0.05 %, Up to SIL 2 acc. to IEC 61508
    
    KFD2-SR2-Ex2.W.SM
    Standstill and Rotational Direction Monitor
    2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Selectable frequency trip values, 2 relay contact outputs, Start-up override, Selectable mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508
    
    KFD2-STC3-Ex1
    SMART Transmitter Power Supply
    1-channel isolated barrier, 24 V DC supply (Power Rail), 2-wire SMART transmitter, Output 4 mA ... 20 mA, SMART capable up to 40 kHz (-1dB), Suitable for Honeywell DE protocol, Terminals with test points
    
    KFD2-UFT-Ex2.D
    Frequency Converter with Direction and Synchronization Monitor
    2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Input frequency 1 mHz ... 1 kHz, Current output 0/4 mA ... 20 mA, Relay contact and transistor output, Start-up override, Configurable by PACTware or keypad, Line fault detection (LFD)
    
    KFD2-UT2-Ex1-1
    Universal Temperature Converter
    1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511
    
    KFD2-VM-Ex1.35.L
    Solenoid Driver
    1-channel isolated barrier, 24 V DC supply (Power Rail), Output 15.3 V DC at 17 mA, 3 logic inputs with AND/OR logic, Service port for isolator function test, Input: with prelogic
    
    KFD2-WAC2-Ex1.D
    Strain Gauge Converter
    1-channel isolated barrier, 24 V DC supply (Power Rail), Strain gauge input (full or half bridge), Output 0 mA ... ± 20 mA or 0 V ... ± 10 V, 2 relay contact outputs, Programmable high/low alarm, Configurable by PACTware or keypad, RS-485 interface, Line fault detection (LFD)
    
    KFD0-CS-Ex1.52
    Repeater
    1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, Accuracy 0.1 %, Entity parameter Io/Isc = 0 mA, Transfer direction: to the control system
    
    KFD0-CS-Ex1.54-Y2
    Repeater
    1-channel isolated barrier, 24 V DC supply (loop powered), SMART fire alarm input, Current input 1 mA ... 20 mA, Transfer direction: to the control system
    
    KFD0-CS-Ex2.50P
    Repeater
    2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Transfer direction: to the field / to the control system
    
    KFD0-LGH
    Place Holder Barrier
    IS K-System place holder module, Housing width 20 mm, Marshalling for field and control side circuits, Configurable via plug-in jumpers
    
    KFD0-LGH-5T
    Place Holder Barrier
    IS K-System place holder module, Housing width 20 mm, Marshalling for field and control side circuits, Configurable via plug-in jumpers, Two additional green terminal blocks supplied separately
    
    KFD0-LGH-GN
    Place Holder Barrier
    IS K-System place holder module, Housing width 20 mm, Marshalling for field and control side circuits, Configurable via plug-in jumpers
    
    KFD0-LGH-Y34868
    Place Holder Barrier
    Non-IS K-System place holder module, Housing width 20 mm, Marshalling for field and control side circuits, No electrical function: empty housing
    
    KFD0-LGH-Y39343
    Place Holder Barrier
    IS K-System place holder module, Housing width 20 mm, Marshalling for field and control side circuits, Configurable via DIP switches and plug-in jumpers
    
    KFD0-RO-2
    Relay Module
    2-channel ** conditioner, 24 V DC supply (loop powered), Logic input 15 V DC ... 30 V DC, non-polarized, Relay contact output, Up to SIL 3 acc. to IEC 61508
    
    KFD0-RSH-1.1D.F1
    Relay Module
    1-channel ** conditioner, 24 V DC supply (loop powered), Logic input 19 V DC ... 26.5 V DC, non-polarized, Relay contact output for de-energized to safe function, Test pulse immunity, Up to SIL 3 acc. to IEC 61508, Up to PL e acc. to EN/ISO 13849
    
    KFD0-RSH-1.1E.1
    Relay Module
    1-channel ** conditioner, 24 V DC supply (loop powered), Logic input 19 V DC ... 26.5 V DC, non-polarized, Relay contact output for energized to safe function , Test pulse immunity, Up to SIL 3 acc. to IEC 61508
    
    KFD0-TT-1
    Thermocouple Converter
    1-channel ** conditioner, 24 V DC supply (loop powered), Thermocouple input, Output 4 mA ... 20 mA, Internal cold junction compensation, Sensor breakage detection, DIP switch selectable ranges

    上海創(chuàng)弗實(shí)業(yè)有限公司專注于安川伺服電機(jī),羅斯蒙特變送器羅斯蒙特分析儀,庫(kù)伯勒編碼器等

  • 詞條

    詞條說(shuō)明

  • 羅斯蒙特ph電3900-01-12

    羅斯蒙特ph電3900-01-12 3900-02-10艾默生ph玻璃電 羅斯蒙特3900和3900VP pH / ORP組合傳感器用于的pH或氧化/還原電位管道,露天水池或池塘中水溶液的測(cè)量。其魯棒的傳感器設(shè)計(jì)使得羅斯蒙特3900和羅斯蒙特3900VP傳感器被廣泛的應(yīng)用。 3900:通用型 pH/ORP 傳感器 3900-01-10:智能前置放大器,32' 電纜,GPLR pH 玻璃 3

  • Rosemount 499ATrDO 型傳感器

    型號(hào) 499A TrDO PDS 71-499A TrDO 微量溶解氧傳感器Rosemount 499ATrDO 型傳感器 499A TrDO-54-60-VP ? 堅(jiān)固的剛性結(jié)構(gòu); ? 隔膜換方便,**工具 ,**工具; ? 自動(dòng)補(bǔ)償由于溫度變化對(duì)傳感器隔膜滲透性的影響 隔膜滲透性的影響; ? 自動(dòng)壓力平衡,防止隔膜變形; ? **的自耗型設(shè)計(jì)1,內(nèi)部氧量補(bǔ)償 ,內(nèi)部氧量補(bǔ)償,

  • LMS511-11100傳感器LMS511-10100 PRO

    LMS511-11100 Lite訂貨號(hào):1054155產(chǎn)品系列:LMS5xx產(chǎn)品系列:2D LiDAR傳感器 工作區(qū)域:1 m...80 m 分辨率范圍:Standard Resolution 開啟角度:水平的(190°) 外殼防護(hù)等級(jí):IP65,IP67 顏色:灰色(RAL 7032) 集成應(yīng)用:評(píng)估區(qū)域 連接類型:4 x M12圓形插頭連接器 掃描頻率:25 Hz/35 Hz/50 Hz/7

  • 羅斯蒙特499ADO 499AOZ 電流式臭氧傳感器499ACL

    Rosemount? 499AOZ 電流式臭氧傳感器 羅斯蒙特499ADO 499AOZ 電流式臭氧傳感器499ACL羅斯蒙特499ADO 499AOZ 電流式臭氧傳感器499ACL羅斯蒙特499ADO 499AOZ 電流式臭氧傳感器499ACL羅斯蒙特499ADO 499AOZ 電流式臭氧傳感器499ACL Rosemount? 499ADO 溶解氧傳感器 Rosemount? 499ACL 型

聯(lián)系方式 聯(lián)系我時(shí),請(qǐng)告知來(lái)自八方資源網(wǎng)!

公司名: 上海創(chuàng)弗實(shí)業(yè)有限公司

聯(lián)系人: 張曉龍

電 話: 18001664790

手 機(jī): 18001664790

微 信: 18001664790

地 址: 上海松江方松辰塔路2號(hào)

郵 編:

網(wǎng) 址: chuangfusy.b2b168.com

八方資源網(wǎng)提醒您:
1、本信息由八方資源網(wǎng)用戶發(fā)布,八方資源網(wǎng)不介入任何交易過(guò)程,請(qǐng)自行甄別其真實(shí)性及合法性;
2、跟進(jìn)信息之前,請(qǐng)仔細(xì)核驗(yàn)對(duì)方資質(zhì),所有預(yù)付定金或付款至個(gè)人賬戶的行為,均存在詐騙風(fēng)險(xiǎn),請(qǐng)?zhí)岣呔瑁?
    聯(lián)系方式

公司名: 上海創(chuàng)弗實(shí)業(yè)有限公司

聯(lián)系人: 張曉龍

手 機(jī): 18001664790

電 話: 18001664790

地 址: 上海松江方松辰塔路2號(hào)

郵 編:

網(wǎng) 址: chuangfusy.b2b168.com

    相關(guān)企業(yè)
    商家產(chǎn)品系列
  • 產(chǎn)品推薦
  • 資訊推薦
關(guān)于八方 | 八方幣 | 招商合作 | 網(wǎng)站地圖 | 免費(fèi)注冊(cè) | 一元廣告 | 友情鏈接 | 聯(lián)系我們 | 八方業(yè)務(wù)| 匯款方式 | 商務(wù)洽談室 | 投訴舉報(bào)
粵ICP備10089450號(hào)-8 - 經(jīng)營(yíng)許可證編號(hào):粵B2-20130562 軟件企業(yè)認(rèn)定:深R-2013-2017 軟件產(chǎn)品登記:深DGY-2013-3594
著作權(quán)登記:2013SR134025
Copyright ? 2004 - 2024 b2b168.com All Rights Reserved