General Notes

    General Notes on PLC Programming and on Acceptance

    Content

    Notes that could not be taken into account in the online help and the manual.

    What do you need to observe with regard to the installation of STEP 7 Safety?

    After the installation of STEP 7 Safety, your safety program will be shown as inconsistent in the Safety Administration Editor. Initiate compilation of the safety program. You will obtain a consistent safety program as a result. The collective F-signature of your safety program remains unchanged.

    Online functions

    It is not possible to open F-blocks via the Lifelist with STEP 7 Safety. You have to have the corresponding project opened offline in order to use all of the online functions for F-blocks.

    Use the Safety Administration Editor for the offline-online comparison if you wish to view the checksums of F-blocks.

    Upgrading to STEP 7 Safety V16

    After upgrading a project that contains S7-300/400 F-CPUs, we recommend executing the command "Compile > Software (rebuild all blocks)".

    The name of the F-I/O is a component of the name of the associated F-I/O DB. In earlier versions of STEP 7 Safety, it was not always ensured that this component was identical to the name of the F-I/O. This is corrected with the upgrade to STEP 7 Safety V15. This does not change the functionality or the collective signature of your safety program. However, since the names of the F-I/O DBs have changed, you should generate an up-to-date safety summary after the upgrade and add it to your acceptance documents.

    Supplement to the section "CTD: Count down (STEP 7 Safety V16)" and section "CTUD: Count up and down (STEP 7 Safety V16)"

    If you use the CTD or CTUD instruction with version 1.1 in a know-how-protected block, you must open the block by entering the password before compiling in order to change the version of the CTD or CTUD instruction to a version other than V1.1.

    The same applies if you want to change the version of the CTD or CTUD instruction from a version other than V1.1 to version V1.1.

    Compiling the safety program

    The collective F-signature is determined in STEP 7 Safety V15.1 when you compile the safety program and shown in the Safety Administration Editor under "Code signature". The collective F-signature is valid but the safety program can still be inconsistent. This is the case when the hardware configuration is not up-to-date (compiled).

    Compile the hardware configuration to obtain a consistent safety program. The collective F-signature does not change as a result.

    Openness

    Importing and exporting F-blocks is not supported by the Openness command set.

    Start values of tags in the block interface

    You can also assign start values in F-blocks for tags (e. g. in the static selection), and use constants from the TAG table (global constants) or the CONST selection (local constants) for this.

    Note that the F-blocks which use global constants as start values must not be called as a multi-instance because in this case the F-CPU can go into STOP. This is not the case when using local constants as start values.

    To avoid CPU STOP, you have to avoid using global constants as start values, or use only single-instance calls for blocks where this is the case. This applies to the blocks themselves, as well as for all blocks which call these blocks, including everything up to Main Safety (complete call sequence).

    Multiuser Engineering

    Please note that in a local session, it is not possible to check in communication IDBs for Flexible F-Link on the multi-user server. This means you have to make changes to the start values in the server-project view, as they will otherwise be overwritten when updating the local session.



    上海騰希電氣技術(shù)有限公司專注于西門子PLC,V90伺服,V20變頻器等, 歡迎致電 13681875601

  • 詞條

    詞條說明

  • 手動導入設(shè)置

    手動導入設(shè)置可從初始化文件手動導入 TIA Portal 設(shè)置,以覆蓋其他用戶的設(shè)置。操作步驟在“選項”(Options) 菜單中,選擇“設(shè)置”(Settings) 命令。將顯示 TIA Portal 中的設(shè)置信息。在區(qū)域?qū)Ш街?,選擇條目“常規(guī)”(General)。在“導入/導出設(shè)置”(Import/export settings) 區(qū)域中,單擊“導入設(shè)置...”(Import settings.

  • 啟動參數(shù)

    啟動參數(shù)CPU 的啟動特性下面介紹了用于確定 S7-CPU 啟動特性的參數(shù)。期望組態(tài)和實際組態(tài)不匹配時啟動預置組態(tài)是指裝載到 CPU 中的組態(tài)(系統(tǒng)數(shù)據(jù)塊)。 實際組態(tài)是指自動化系統(tǒng)的實際組態(tài)。如果沒有選中“期望組態(tài)和實際組態(tài)不匹配時啟動”(Startup when expected and actual configurations do not match) 復選框,則 CPU 在以下情況下切

  • “保存到條目...”對話框的結(jié)構(gòu)

    “保存到條目...”對話框的結(jié)構(gòu)在“保存到條目...”(Save to item...) 對話框中,用戶可以定義要在 Teamcenter 中保存的 TIA Portal 項目的屬性?!氨4娴綏l目...”對話框的結(jié)構(gòu)“保存到條目...”(Save to item...) 對話框的視圖包含以下字段和按鈕。字段說明名稱 (Name):在 Teamcenter 中保存 TIA Portal 項目時要使用

  • 更換安全模塊

    更換安全模塊要求為了能夠更換安全模塊,安全模塊的模塊描述必須是較新的。要較新安全模塊的模塊描述,請按照下面的步驟操作:選擇要編輯的安全模塊。在本地安全設(shè)置中,單擊“常規(guī) > 目錄信息”(General > Catalog information) 條目。單擊“較新模塊描述”(Update module description) 按鈕。如何訪問該功能在拓撲或網(wǎng)絡視圖中選擇要編輯的安全模塊

標簽:General Notes

聯(lián)系方式 聯(lián)系我時,請告知來自八方資源網(wǎng)!

公司名: 上海騰希電氣技術(shù)有限公司

聯(lián)系人: 田禮科

電 話: 021-37660026

手 機: 13681875601

微 信: 13681875601

地 址: 上海松江上海市松江區(qū)廣富林路4855弄星月大業(yè)**88號4樓

郵 編:

網(wǎng) 址: shtxjd.cn.b2b168.com

八方資源網(wǎng)提醒您:
1、本信息由八方資源網(wǎng)用戶發(fā)布,八方資源網(wǎng)不介入任何交易過程,請自行甄別其真實性及合法性;
2、跟進信息之前,請仔細核驗對方資質(zhì),所有預付定金或付款至個人賬戶的行為,均存在詐騙風險,請?zhí)岣呔瑁?
    聯(lián)系方式

公司名: 上海騰希電氣技術(shù)有限公司

聯(lián)系人: 田禮科

手 機: 13681875601

電 話: 021-37660026

地 址: 上海松江上海市松江區(qū)廣富林路4855弄星月大業(yè)**88號4樓

郵 編:

網(wǎng) 址: shtxjd.cn.b2b168.com

    相關(guān)企業(yè)
    商家產(chǎn)品系列
  • 產(chǎn)品推薦
  • 資訊推薦
關(guān)于八方 | 八方幣 | 招商合作 | 網(wǎng)站地圖 | 免費注冊 | 一元廣告 | 友情鏈接 | 聯(lián)系我們 | 八方業(yè)務| 匯款方式 | 商務洽談室 | 投訴舉報
粵ICP備10089450號-8 - 經(jīng)營許可證編號:粵B2-20130562 軟件企業(yè)認定:深R-2013-2017 軟件產(chǎn)品登記:深DGY-2013-3594
著作權(quán)登記:2013SR134025
Copyright ? 2004 - 2025 b2b168.com All Rights Reserved